Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/5053
Title: Validity of Body-Composition Methods across Racial and Ethnic Populations
Authors: Blue, Malia NM
Tinsley, Grant M
Ryan, Eric D
Smith-Ryan, Abbie E
Keywords: body fat percentage
fat-free mass
validation
multi-ethnic
African American
Hispanic
Asian
Native American
Issue Date: 2021
Publisher: Advances in Nutrition
Series/Report no.: Review;1854-1862
Abstract: Multi-compartment body-composition models that divide the body into its multiple constituents are the criterion method for measuring body fat percentage, fat mass, and fat-free mass. However, 2- and 3-compartment body-composition devices such as air displacement plethysmography (ADP), DXA, and bioelectrical impedance devices [bioelectrical impedance analysis (BIA)] are more commonly used. Accurate measures depend on several assumptions, including constant hydration, body proportion, fat-free body density, and population characteristics. Investigations evaluating body composition in racial and ethnic minorities have observed differences in the aforementioned components between cohorts. Consequently, for racial/ethnic minority populations, estimates of body composition may not be valid. The purpose of this review was to comprehensively examine the validity of common body-composition devices in multi-ethnic samples (samples including>1 race/ethnicity) and in African-American, Hispanic, Asian, and Native American populations. Based on the literature, DXA produces valid results in multi-ethnic samples and ADP is valid for Hispanic and African American males when utilizing race-specific equations. However, for DXA and ADP, there is a need for validity investigations that include larger, more racially diverse samples, specifically including Hispanic/Latinx, Asian, Native American adults, and African-American females. Technology has advanced significantly since initial validity studies were conducted; therefore, conclusions are based on outdated models and software. For BIA, body-composition measures may be valid in a multi-ethnic sample, but the literature demonstrates disparate results between races/ethnicities. For BIA and ADP, the majority of studies have utilized DXA or hydrostatic weighing as the criterion to determine validity; additional studies utilizing a multi-compartment model criterion are essential to evaluate accuracy. Validity studies evaluating more recent technology in larger, more racially/ethnically diverse samples may improve our ability to select the appropriate method to accurately assess body composition in each racial/ethnic population
URI: http://localhost:8080/xmlui/handle/123456789/5053
Appears in Collections:VOL 12 NO 6 (2021)

Files in This Item:
File Description SizeFormat 
1854-1862.pdf230 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.