Please use this identifier to cite or link to this item:
http://localhost:8080/xmlui/handle/123456789/8955
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gunawan, Evan Jim | - |
dc.contributor.author | Johan | - |
dc.contributor.author | Munawar, Dian Andina | - |
dc.contributor.author | Munawar, Dian Larasati | - |
dc.contributor.author | Hartono, Beny | - |
dc.contributor.author | Munawar, Muhammad | - |
dc.date.accessioned | 2024-12-14T03:00:45Z | - |
dc.date.available | 2024-12-14T03:00:45Z | - |
dc.date.issued | 2024-04 | - |
dc.identifier.citation | Case Report | en_US |
dc.identifier.uri | http://localhost:8080/xmlui/handle/123456789/8955 | - |
dc.description.abstract | Left bundle branch pacing (LBBP) has been subject to increasing interest over the last few years due to its capacity for physiological conduction and its advantages compared to His bundle pacing. His bundle pacing has certain limitations, such as a small pacing area for the His bundle, a high threshold that leads to battery depletion, a low R-wave amplitude that may result in atrial or His oversensing, and ventricular signal undersensing. In this case series, four patients (two female and two male) aged 62.2 ± 8.4 years old with symptomatic sick sinus disease and no scar tissue in the interventricular septum underwent LBBP. All LBBPs were done with standard LBBP using a lumenless SelectSecure 3830 lead (Medtronic®, Minneapolis, USA) with a fixed helix. The lead parameters showed a good R-wave amplitudes (13 ± 7.4 mV) and a low threshold (0.77 ± 0.17 V @ 0.4 ms). All patients were discharged on the next day. During follow-up period of 13.3 ± 12.9 months, all patients were well and no complications were noted. In conclusion, LBBP may be as an alternative of novel conduction pacing techniques and can be done relatively easy and safe, even with limited experience center. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Acta Medica Indosiana | en_US |
dc.subject | Left bundle branch pacing | en_US |
dc.subject | novel conduction system pacing | en_US |
dc.subject | sick sinus syndrome | en_US |
dc.subject | pacemaker | en_US |
dc.title | Early Experience of Left Bundle Branch Pacing with Lumenless Lead in a Single Center: A Case Series | en_US |
dc.type | Article | en_US |
Appears in Collections: | VOL 56 NO 2 2024 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
227-232.pdf | 2.59 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.