Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/8880
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDimas Asmara, Oke-
dc.contributor.authorWicaksono Pitoyo, Ceva-
dc.contributor.authorWulani, Vally-
dc.contributor.authorHarimurti, Kuntjoro-
dc.contributor.authorP. Araminta, Abrianty-
dc.date.accessioned2024-12-13T02:25:15Z-
dc.date.available2024-12-13T02:25:15Z-
dc.date.issued2022-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/8880-
dc.description.abstractBackground: There is a stigma that ultrasound cannot be used to see abnormalities in the air-filled organs makes ultrasound rarely used to identify lung abnormalities. This study purpose comparing diagnostic accuracy of BLUE protocol with gold standard for each diagnosis causing acute respiratory failure. Methods: Systematic search was done in 6 databases (Pubmed/MEDLINE, Embase, Cochrane Central, Scopus, Ebscohost/CINAHL dan Proquest) and multiple grey-literature sources for cross-sectional studies. We manually extracted the data from eligible studies and calculated pooled sensitivity, pooled specificity, likelihood ratio (LR) and diagnostic odds ratio (DOR). We follow PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guideline throughout these processes. Results: Four studies has been picked from total 509 studies involved. The results yield parameters indicating BLUE protocol as a reliable modality to diagnose pneumonia with pooled sensitivity 84% (95% CI, 76-89%), pooled specificity 98% (95% CI, 93-99%), LR+ 42 (95% CI, 12-147), LR- 0.12 (95% CI, 0.07-0.2) and DOR 252 (95% CI, 81-788), respectively. It also considerably applicable to diagnose pulmonary oedema with pooled sensitivity 89% (95% CI, 81-93%), pooled specificity 94% (95% CI, 89-96%), LR+ 14 (95% CI, 8-25), LR- 0.165 (95% CI, 0.11-0.24), and DOR 116 (95% CI, 42-320), respectively. Conclusion: BLUE protocol has good diagnostic accuracy to diagnose pneumonia and pulmonary oedema. We recommend implementing BLUE protocol as a tool in evaluating cause of ARF. Keywords: Ultrasonography, BLUE protocol, Accuracy, Respiratory Failure, Meta-analysisen_US
dc.subjectUltrasonography, BLUE protocol, Accuracy, Respiratory Failure, Meta-analysisen_US
dc.titleAccuracy of Bedside Lung Ultrasound in Emergency (BLUE) Protocol to Diagnose the Cause of Acute Respiratory Distress Syndrome (ARDS): A Meta-Analysisen_US
dc.typeArticleen_US
Appears in Collections:VOL 54 NO 2 2022

Files in This Item:
File Description SizeFormat 
10.pdf1.56 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.