Please use this identifier to cite or link to this item:
http://localhost:8080/xmlui/handle/123456789/8466
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Altaie, Amani Abduljabar | - |
dc.contributor.author | Alkhalidi, Emad Farhan | - |
dc.date.accessioned | 2024-11-26T06:59:45Z | - |
dc.date.available | 2024-11-26T06:59:45Z | - |
dc.date.issued | 2024-01 | - |
dc.identifier.uri | http://localhost:8080/xmlui/handle/123456789/8466 | - |
dc.description.abstract | Objective: The goal of this research is to investigate the effect of plasma surface treatment on retentive strength (RS) between the (5)Yttrium Zirconia coping and the titanium implant abutment (Dentium system) using self-adhesive resin cement. Methods: forty standard titanium implant abutments of 5.5 mm height and 4.5 mm in diameter were screwed with implant laboratory analogs embedded vertically in autopolymerizing acrylic resin blocks, forty Zirconia copings with a hole on the occlusal surface were fabricated using CAD/CAM system. Samples were divided into four groups (n 10 for each group); Group (1) no plasma surface treatment for implant abutment and coping (act as control). Group (2) plasma surface treatment for implant abutment only. Group (3) plasma surface treatment for coping only. Group (4)plasma surface treatment for implant abutment and coping. Coping of all groups were cemented with implant abutment by Allcem dual cure resin cement. All cemented samples were (5000) cycles of thermocycling process and then tensile bond strength evaluated by Universal testing machine, Following the tensile bond strength test, each debonded surface was examined by stereomicroscope at a 20x magnification. The one-way analysis of variance and Duncan test were used to statistically examine the experimental results. Results: Plasma surface treatment had observed effect that increase tensile bond strength between titanium implant abutment and (5) yttrium Zirconia coping, plasma surface treatment for abutment and coping (Group 4) was the highest value of tensile strength followed by abutment plasma surface treatment (Group 2), while lowest value of tensile bond strength in control group (Group 1) and coping plasma surface treatment (Group 3). Conclusion: Plasma surface treatment increase tensile bond strength between implant abutment and zirconia coping. Plasma surface treatment for both abutment and coping provided higher tensile bond strength. Mode of failure was adhesive failure occurs in abutment surface. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Pharmacognosy Journal | en_US |
dc.subject | Plasma | en_US |
dc.subject | Titanium abutment | en_US |
dc.subject | (5)Y Zirconia | en_US |
dc.subject | Tensile bond strength | en_US |
dc.title | Effect of Plasma Treatment on Tensile Bond Strength of (5) Yttrium Zirconia Coping Fixed on Titanium Implant Abutment | en_US |
dc.type | Article | en_US |
Appears in Collections: | VOL 16 NO 1 2024 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
204-210.pdf | 539.9 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.