Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/8452
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKomang Agung Cahyadi, I Dewa-
dc.contributor.authorWande, I Nyoman-
dc.contributor.authorMahartini, Ni Nyoman-
dc.date.accessioned2024-11-26T04:16:59Z-
dc.date.available2024-11-26T04:16:59Z-
dc.date.issued2023-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/8452-
dc.description.abstractBackground: Sysmex DI-60 and Sysmex XN-1000 are automatic analyzers that can be used to check WBC differential counts. Ensuring the suitability of the WBC differential count results from the two tools can help in daily practice. Objective: Knowing the suitability of the WBC differential count examination results on the Sysmex DI-60 and Sysmex XN-1000. Method: Observational analytical research with a cross-sectional design. The data analyzed were differential WBC count data from samples of babies who underwent Complete Blood Count examinations on the Sysmex XN-1000 device and IT Ratio on the Sysmex DI-60 device without intervention (pre-classification results) at the Clinical Pathology Laboratory, Prof. Head overMarch 2023 – April 2023. Results: 81 samples were analyzed. The neutrophil value on the Sysmex DI-60 and Sysmex vs 34.15% ± 14.83%, median monocytes 4.00% (0.00-30.00)% vs 13.05% (1.30-34.40) %, median eosinophils 3.50% (0.00-31.00)% vs 3.75% (0.00-29.90)%, and median basophils 0.75% (0.00-16.00)% vs 0.30% (0, 00-2.90)%. The eosinophil variable did not show a significant difference between the results of the Sysmex DI-60 and Sysmex XN-1000 examinations (p=0.081). The results of the correlation analysis showed that there was a significant, strong, positive correlation between Sysmex DI- 60 and Sysmex. Strong positive significance in the lymphocyte variable (r=0.818). However, no significant correlation basophil variable (r=0.044). Bland-Altman analysis shows that the most appropriate differential count examination is the eosinophil variable. Conclusion: Automatic WBC analyzers apply not only one examination method to detect WBC. The use of the Sysmex DI-60 and Sysmex XN-1000 provides automation for checking the WBC differential count with different working principles. In this study, there was only agreement between the differential count results for the eosinophil variable, so when operating these tools, intervention from a Clinical Pathologist was still required. Key words: Differential Count, WBC, DI-60, XN-1000.en_US
dc.subjectDifferential Count,en_US
dc.subjectWBC, DI-60, XN-1000.en_US
dc.titleConformity of Differential White Blood Cell (WBC) Examination Results on the Sysmex DI-60 And Sysmex XN-1000 at Prof. Dr. IGNG Ngoerah General Hospital, Denpasar, Balien_US
dc.typeArticleen_US
Appears in Collections:VOL 15 NO 6 2023

Files in This Item:
File Description SizeFormat 
14.pdf394.24 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.